P2HZ X4P
Operating Manual P2HZ X4P
20076-EN-08
7
Unit features
}
Positive-guided relay outputs:
–
3 safety contacts (N/O), instantaneous
–
1 auxiliary contact (N/C), instantaneous
}
Connection options for:
–
2 control elements (pushbuttons)
}
LED display for:
–
Supply voltage
–
Switch status of the safety contacts
}
Plug-in connection terminals (either spring-loaded terminal or screw terminal)
Safety features
The two-hand control relay meets the following safety requirements:
}
The circuit is redundant with built-in self-monitoring.
}
The safety function remains effective in the case of a component failure.
}
The circuit prevents a further press stroke in the case of:
–
Relay failure
–
Contact welding
–
Coil defect on a relay
–
Open circuit
–
Short circuit