5.3
Connecting two or more servo amplifiers with a DC link system
to a Dynamic Energy Storage Unit
Only one servo amplifier has a brake resistor
⌧
Connect the Dynamic Energy Storage Unit to this servo amplifier.
⌧
Connect the brake resistor line to this servo amplifier.
Several servo amplifiers have a brake resistor and it is certain
that all servo amplifiers always brake at the same time
⌧
Connect the Dynamic Energy Storage Unit to any servo amplifier.
⌧
Connect the brake resistor line to the same servo amplifier.
Several servo amplifiers have a brake resistor and it is not certain that all servo
amplifiers always brake at the same time
(only for Dynamic Energy Storage Unit with a fixed setting for the working
voltage on the DC link)
⌧
Connect the Dynamic Energy Storage Unit to any servo amplifier.
⌧
Do not connect the brake resistor line (fixed default setting).