Commissioning
Operating Manual PMCprimo MC
1003813-EN-03
| 54
7.2.6
Operate PMCprimo MC HW2 - Show hardware
HW2 - Show Hardware State
0.1: HW2
0.1:
STATE OF DEVICES:
Device
Network Addr
CH
FS
VN
State
------------------------------------------------------------------------------
PMCprimo MC
---
---
---
--- 03.05.00
ACTIVE
PMCtendo DD4
CAN4
6
---
--- 5.180
FAULT
PMCprotego D
ECAT
51
---
--- 6.22
ACTIVE
7.3
Install CODESYS
The development environment for programming in accordance with IEC 61131-3
CODESYS can be found in the software package "PMC Programming Tool". The software
package is available on the Internet at www.pilz.de.
After downloading
a
Unpack the Zip file,
a
Start the installation program.
The PMCprimo Target Package is installed.