"Startup" operating status has been run without error. The system changes to "STOP"
status if
no
user program was loaded in "Startup" status.
1
-->
5
Change from "Startup" to "Fatal Error"
The system changes to "Fatal Error" status if an error occurred in "Startup" status.
2
-->
1
Change from "Boot Menu" to "Startup"
The system changes to "Startup" status if the "Boot Menu" in the terminal program is exited
using the command O or ESC.
3
-->
1
Change from "RUN" to "Startup"
The system performs a hardware reset after
}
Running the command RS1 in the terminal program (cold start).
}
Holding down the reset button for a long period (> 4 s) (alternative to RS1 command).
3
-->
4
Change from "RUN" to "STOP"
The system performs this status change after
}
Running the following commands in the terminal program:
– RS3 (change to "STOP")
– RS4 (warm reset), stops the user program
– RS5 (cold reset), stops the user program
– RS5 (original reset), deletes the user program
}
Running commands in the IEC 61131 development environment.
}
Holding down the reset button for a short period (< 4 s) (alternative to RS3 command,
change to "STOP").
3
-->
5
Change from "RUN" to "Fatal Error"
The system changes to "Fatal Error" status if an error occurred in "RUN" status.
Remedy
}
Delete user program
}
Firmware update
4
-->
1
Change from "STOP" to "Startup"
The system performs a hardware reset after
}
Running the command RS1 in the terminal program (cold start).
}
Holding down the reset button for a long period (> 4 s) (alternative to RS1 command (cold
start)).
4
--
>
3
Change from "STOP" to "RUN"
The system performs this status change after
}
Running the command RS2 in the terminal program (change to "RUN").
}
Running commands in the IEC 61131 development environment: