background image

PNOZ c2

Operating Manual PNOZ c2
22212­EN­02

4

Introduction

Validity of documentation

This documentation is valid for the product PNOZ c2. It is valid until new documentation is
published.

This operating manual explains the function and operation, describes the installation and
provides guidelines on how to connect the product.

Retaining the documentation

This documentation is intended for instruction and should be retained for future reference.

Definition of symbols

Information that is particularly important is identified as follows:

DANGER!

This warning must be heeded! It warns of a hazardous situation that poses
an immediate threat of serious injury and death and indicates preventive
measures that can be taken.

WARNING!

This warning must be heeded! It warns of a hazardous situation that could
lead to serious injury and death and indicates preventive measures that can
be taken.

CAUTION!

This refers to a hazard that can lead to a less serious or minor injury plus
material damage, and also provides information on preventive measures
that can be taken.

NOTICE

This describes a situation in which the product or devices could be dam­
aged and also provides information on preventive measures that can be
taken. It also highlights areas within the text that are of particular import­
ance.

Summary of Contents for PNOZ c2

Page 1: ...PNOZ c2 Operating Manual 22212 EN 02 Safety relays...

Page 2: ...KG Copies may be made for internal purposes Suggestions and comments for improving this documentation will be gratefully received Pilz PIT PMI PNOZ Primo PSEN PSS PVIS SafetyBUS p SafetyEYE SafetyNET...

Page 3: ...r your safety 5 Unit features 5 Safety features 6 Block diagram terminal configuration 6 Function description 6 Installation 7 Wiring 7 Preparing for operation 7 Operation 9 Status indicators 9 Faults...

Page 4: ...This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measures that can be taken WARNING This warning must b...

Page 5: ...with the documented technical details For your safety Only install and commission the unit if you have read and understood these operating instructions and are familiar with the applicable regulation...

Page 6: ...The unit is ready for operation when the start circuit is closed or when a start contact is opened and closed again in the start circuit High signal at input circuit e g light guard nor interrupted Th...

Page 7: ...welding a fuse should be connected before the output contacts see Technical details Use copper wire that can withstand 60 75 C Do not connect capacitive load The power supply must comply with the reg...

Page 8: ...ht guard Use the free connections A1 and A2 for connecting the supply voltage of the sender Start circuit feedback loop Start circuit Feedback loop automatic start monitored start NOTICE The unit auto...

Page 9: ...ircuit has opened Technical details General 710002 Approvals CCC CE EAC Eurasian T V cULus Listed Electrical data 710002 Supply voltage Voltage 24 V Kind DC Voltage tolerance 20 20 Output of external...

Page 10: ...contacts DC 1 at 24 V Max current 4 0 A Min current 0 01 A Max power 100 W Utilisation category In accordance with the standard EN 60947 5 1 Safety contacts AC15 at 230 V Max current 1 5 A Safety con...

Page 11: ...0 ms Simultaneity channel 1 and 2 Environmental data 710002 Climatic suitability EN 60068 2 78 Ambient temperature Temperature range 10 55 C Storage temperature Temperature range 40 85 C EMC EN 60947...

Page 12: ...62061 SIL CL EN IEC 62061 PFHD 1 h IEC 61511 SIL IEC 61511 PFD EN ISO 13849 1 2008 TM year Safety con tacts in stantaneous PL e Cat 4 SIL CL 3 2 31E 09 SIL 3 2 03E 06 20 INFORMATION All the units use...

Page 13: ...on the relay output If the service life graphs are not accessible the stated PFH value can be used irrespective of the switching frequency and the load as the PFH value already considers the relay s B...

Page 14: ...must be provided on all output contacts With DC contactors use flywheel diodes for spark suppression Order reference Type Features Terminals Order no PNOZ c2 24 VDC With spring loaded terminals 710 0...

Page 15: ...raNET p Pilz PIT PMCprotego PMI PNOZ Primo PSEN PSS PVIS SafetyBUS p SafetyEYE SafetyNET p the spirit of safety are registered and protected trademarks of Pilz GmbH Co KG in some countries We would po...