Service life graphs at 110 V DC
Example
}
Inductive load: 0.2 A
}
Utilisation category: AC15
}
Contact service life: 1 000 000 cycles
Provided the application requires fewer than 1 000 000 cycles, the PFH value (see tech
nical details) can be used in the calculation.
To increase the service life, sufficient spark suppression must be provided on all output
contacts. With DC contactors, use flywheel diodes for spark suppression.
Order reference
Type
Features
Terminals
Order no.
PNOZ c2
24 VDC
With springloaded terminals
710 002
EC declaration of conformity
This product/these products meet the requirements of the directive 2006/42/EC for ma
chinery of the European Parliament and of the Council. The complete EC Declaration of
Conformity is available on the Internet at www.pilz.com/downloads.
Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, FelixWankelStr. 2, 73760 Ost