Technical details
Operating Manual PNOZ m B0
1002660-EN-07
33
Configurable inputs/outputs (inputs or auxiliary
outputs)
Configurable auxiliary outputs
Voltage
24 V
Output current
75 mA
Output current range
0 - 100 mA
Max. transient pulsed current
500 mA
Short circuit-proof
yes
Residual current at "0"
0,5 mA
Voltage at "1"
UB - 2 V at 0.1 A
Inputs
Number
12
Input voltage in accordance with EN 61131-2 Type 1
24 V DC
Input current at rated voltage
5 mA
Input current range
2,5 - 5,3 mA
Pulse suppression
0,5 ms
Maximum input delay
2 ms
Potential isolation
No
Semiconductor outputs
Number of positive-switching single-pole semicon-
ductor outputs
4
Switching capability
Voltage
24 V
Current
2 A
Permitted current range
0,000 - 2,500 A
Residual current at "0" signal
0,05 mA
Max. transient pulsed current
12 A
Max. capacitive load
1 µF
Max. internal voltage drop
500 mV
Max. duration of off time during self test
330 µs
Switch-off delay
1 ms
Potential isolation
yes
Short circuit-proof
yes
Test pulse outputs
Number of test pulse outputs
4
Voltage
24 V
Current
0,1 A
Max. duration of off time during self test
5 ms
Short circuit-proof
yes
Potential isolation
No
Times
Simultaneity in the two-hand circuit
0,5 s
Processing time
30 ms