background image

PNOZ pe2p

Operating Manual PNOZ pe2p
21035-EN-03

6

Safety regulations

Use of qualified personnel

The products may only be assembled, installed, programmed, commissioned, operated,
maintained and decommissioned by competent persons.
A competent person is someone who, because of their training, experience and current pro-
fessional activity, has the specialist knowledge required to test, assess and operate the
work equipment, devices, systems, plant and machinery in accordance with the general
standards and guidelines for safety technology.
It is the company’s responsibility only to employ personnel who:

}

Are familiar with the basic regulations concerning health and safety / accident preven-
tion

}

Have read and understood the information provided in this description under "Safety"

}

And have a good knowledge of the generic and specialist standards applicable to the
specific application.

Warranty and liability

All claims to warranty and liability will be rendered invalid if

}

The product was used contrary to the purpose for which it is intended

}

Damage can be attributed to not having followed the guidelines in the manual

}

Operating personnel are not suitably qualified

}

Any type of modification has been made (e.g. exchanging components on the PCB
boards, soldering work etc.).

Disposal

}

When decommissioning, please comply with local regulations regarding the disposal of
electronic devices (e.g. Electrical and Electronic Equipment Act).

Summary of Contents for PNOZ pe2p

Page 1: ...PNOZ pe2p Operating Manual 21035 EN 03 Safety relays...

Page 2: ...umentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Interne...

Page 3: ...e 5 Safety regulations 6 Use of qualified personnel 6 Warranty and liability 6 Disposal 6 Unit features 7 Block diagram terminal configuration 7 Function Description 7 Operating modes 7 Installation 8...

Page 4: ...arly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measure...

Page 5: ...put modules PNOZelog range units The bus interface may only be used in conjunction with units that evaluate a feedback loop The following is deemed improper use in particular Any component technical o...

Page 6: ...with the basic regulations concerning health and safety accident preven tion Have read and understood the information provided in this description under Safety And have a good knowledge of the generi...

Page 7: ...hen supply voltage is applied and the feedback loop Y1 Y2 is closed 24 V DC are available at the terminal K1 e g the PSS output has a high signal At the expansion module control output connected to th...

Page 8: ...Zpower Layout The PNOZ pe2p is installed on the left of the first expansion module Maximum hardware 1 bus interface 6 expansion modules Expansion module 1 Expansion module 2 Expansion module 6 95579 T...

Page 9: ...st always be supplied by a single power supply The power supply must comply with the regulations for extra low voltages with protect ive electrical separation SELV PELV in accordance with VDE 0100 Par...

Page 10: ...oltage at Input circuit DC 24 V Feedback loop DC 24 V Current at Input circuit DC 30 mA Feedback loop DC 1 A Environmental data Climatic suitability EN 60068 2 78 Ambient temperature Temperature range...

Page 11: ...p connectors or with TWIN crimp connectors 0 5 1 5 mm 28 14 AWG Torque setting with screw terminals 0 25 Nm Dimensions Height 29 mm Width 23 5 mm Depth 22 5 mm Weight 15 g Where standards are undated...

Page 12: ...T p ThE SPIrIT Of SAfETY are registered and protected trademarks of Pilz Gmbh Co KG in some countries We would point out that product features may vary from the details stated in this document dependi...