PNOZ X13
Operating Manual PNOZ X13
20187-EN-07
| 12
Start circuit
E-STOP wiring
Safety gate without start-up
test
Safety gate with start-up test
Automatic start
S33
S34
S13
S14
S33
S13
S34
S14
Monitored start
S33
S34
S3
S14
S13
NOTICE
In the event of an automatic start:
The unit starts up automatically when the safeguard is reset, e.g. when the
E-STOP pushbutton is released. Use external circuit measures to prevent
an unexpected restart.
Feedback loop
Automatic start
Monitored start
Contacts from external contactors
K5
K6
K5
L1
N
K6
S13
13 (23 ... 53)
S14
14 (24 ... 54)
K5
K6
K5
L1
K6
S33
S34
S3
N
13 (23 ... 53)
14 (24 ... 54)
Legend
}
S1/S2: E-STOP/safety gate switch
}
S3: Reset button
}
: Switch operated
}
: Gate open
}
: Gate closed
INFORMATION
With automatic start, S33 and S34 must not be linked; with monitored
start, S13 and S14 must not be linked.