PSEN ma1.3p-20
Operating Manual PSEN ma1.3p-20
22147-EN-05
| 12
NOTICE
The auxiliary contact with LED
– May only be operated with a supply voltage of up to 24 VDC with
PNOZ X units
– May not be connected in series with PNOZ X, PNOZelog and
PNOZmulti units
– may
not
be used for safety circuits
Requirements and connection to evaluation devices
For use of PSEN ma1.3p-20 in accordance with DIN EN 60947-5-3 an evaluation device
must be connected.
Connect the PSEN ma1.3p-20
}
either
with a certified Pilz evaluation device
}
or
with an evaluation device with defined properties
Certified Pilz evaluation devices are, for example:
}
PNOZelog for safety gate monitoring
– PNOZ e1p, PNOZ e1.1p, PNOZ e1vp
– PNOZ e5.11p
– PNOZ e6vp, PNOZ e6.1p
}
PNOZpower for safety gate monitoring
– PNOZ p1p, PNOZ p1vp
}
PNOZsigma for safety gate monitoring
– PNOZ s3
– PNOZ s4
– PNOZ s5
}
PNOZ X for safety gate monitoring
– PNOZ X2, PNOZ X2.5P, PNOZ X2.7P, PNOZ X2.8P, PNOZ X2.9P, PNOZ X2C
– PNOZ X3, PNOZ X3.1, PNOZ X3P, PNOZ X3.10P
– PNOZ X4
– PNOZ X5, PNOZ X5J
– PNOZ Ex
}
PNOZmulti for safety gate monitoring
Configure the switch in the PNOZmulti Configurator with switch type 3.
}
PSS for safety gate monitoring with standard function block SB064, SB066 or
FS_Safety Gate
}
PSSuniversal PLC for safety gate monitoring with function block FS_SafetyGate