Environmental data
506226
506236
Airgap creepage
Pollution degree
3
3
Rated insulation voltage
25 V
25 V
Rated impulse withstand voltage
0,33 kV
0,33 kV
Protection type
Housing
IP65
IP65
Mechanical data
506226
506236
Actuator 1
PSEN ma1.3-08
PSEN ma1.3-12
Typ. Hysteresis
2 mm
2,5 mm
Operating distances
Assured operating distance Sao
8 mm
12 mm
Min. operating distance Somin
0,5 mm
0,5 mm
Typical operating distance So
10 mm
14 mm
Assured release distance Sar
15 mm
25 mm
Typical release distance Sr
12 mm
16 mm
Repetition accuracy switching
distances
5 %
5 %
Min. distance between safety
switches
25 mm
35 mm
Sensor flush installation in accord-
ance with EN 60947-5-2
Yes, follow installation
guidelines
Yes, follow installation
guidelines
Connection type
M8, 8-pin male connector
M8, 8-pin male connector
Cable
Li9Y11Y 8 x 0,14 mm2
Li9Y11Y 8 x 0,14 mm2
Material
Top
PBT
PBT
Max. torque setting
Safety switch
3 Nm
3 Nm
Actuator 1
3 Nm
0,1 Nm
Dimensions
Height
11 mm
11 mm
Width
12 mm
12 mm
Depth
59,1 mm
59,1 mm
Actuator dimensions
Height
11 mm
11 mm
Width
12 mm
12 mm
Depth
25 mm
25 mm
Weight of safety switch
20 g
20 g
Weight of actuator
11 g
11 g
Weight
30 g
30 g
Where standards are undated, the 2015-09 latest editions shall apply.