PSEN ma1.4n-51
Operating Manual PSEN ma1.4n-51
22131-EN-06
| 9
Lateral and vertical offset
[1]
[2]
Legend
[1] Lateral offset
[2] Vertical offset
Actuator PSEN ma1.4-03
Assured operating distance S
ao
in mm
Vertical offset
Lateral offset
0
1
2
3
4
0
3.0
3.0
2.5
1.5
1.0
1
3.0
2.5
2.0
0.5
-
2
2.5
1.5
1.0
-
-
3
1.5
0.5
-
-
-
4
0.5
-
-
-
-
The stated values are valid at a temperature of 20 °C.
Actuator PSEN ma1.4-10
Assured operating distance S
ao
in mm
Vertical offset
Lateral offset
0 mm
2 mm
4 mm
6 mm
8 mm
0 mm
10.0
10.0
9.0
7.0
5.0
2 mm
10.0
10.0
8.0
6.0
3.0
4 mm
9.0
8.0
7.0
5.0
-
6 mm
7.0
6.0
5.0
-
-
The stated values are valid at a temperature of 20 °C.