Installation type 2
Install the sensor as shown for installation type 1
}
1. Attach the screws for the actuator, maintaining the distance between the screw head
and the plate: ca. 3 ... 6 mm.
}
2. Close unused mounting holes on the plate using seal (2) (see
).
}
3. Slide the actuator on to the screws.
}
4. Align actuator and tighten screws with max. 0,8 Nm.
}
5. Close used mounting holes using seal (1) or (4) (see
).
}
6. Close mounting holes on the sensing face using seal (3) (see
Diagram [
}
7. Installation of sensor and actuator is now complete.
1
2
3
4
5
6
7
INFORMATION
Seals (1), (2), (3) meet the requirements of UL 94 V0, seal (4) does
not