Function description
Operating Manual PSEN op2B/1 Series
1003357-EN-02
19
Fig.: Muting in two directions: Expansion with external muting sensors
CAUTION!
If the safety light grid is in a muting status, the OSSDs continue to be
switched on
The connected machine remains in operation and so represents a potential
hazard.
– Prevent access to the danger zone during muting.
Identification of the conveyed material (pallets, vehicles...) must be guaranteed with all
}
Material dimensions and
}
Conveyor speeds
that are intended to arise during operation.
Different conveyor speeds in the area of the safety light grid should be prevented.
4.5.1
Technical implementation
The safety light grid
has two inputs, Muting 1 and Muting 2, to activate the muting function.
The muting sensors are connected to these inputs. The muting sensors must be positioned
and installed at a right angle to the receiver and transmitter (see
Installation and
wiring [
35]
).
}
The muting status occurs
– when the first sensor and the second sensor detect a conveyed material simultan-
eously or
– when the first sensor has detected a conveyed material and the second sensor also
detects it max. 4 s afterwards.