Assignment of M12 connector
12-pin
5-pin
PSENopt Advanced RX Muting
CONNECTION
LINE
BEHAVIOUR
RESET
24Vdc
IN line
N.O.
Is connected – when in disabled state the
RESET/RESTART/ALIGN button is operated
RESTART
24Vdc
IN line
N.O.
Is connected – when during operation the
RESET/RESTART/ALIGN button is operated
ALIGNMENT
24Vdc
IN line
N.O.
Has to be set to 24 V DC at startup
OVERRIDE 1
24Vdc
IN line
N.O.
Is connected – when Override is active during
operation
OVERRIDE 2
IN line
N.O.
No voltage – during operation
EDM
See section 7.4 for
connections
Must be non-equivalent to OSSD during operation
with EDM enabled
MUTING
DEACTIVATION
24Vdc
IN line
N.O.
Muting is disabled when connecting
OSSD1 / OSSD 2
0V
OSSDs
Protected field clear
No voltage = Protected field not clear
OVERRIDE
STATUS
0V
OSSDs
High level = Override function active
Low level = Override function inactive
NOTE: This line signals the state of the override
signal inputs
MUTING LAMP
24Vdc
LAMP
The open collector connection is activated when
muting is activated.
MUTING1/MUTING2
24Vdc
IN line
N.O.
Is connected – when muting is active during
operation
FUNCTION EARTH
Connect to earth
PSENopt Advanced TX
CONNECTION
LINE
BEHAVIOUR
TEST
24Vdc
IN line
N.O.
Is connected – when the RESET button is
operated during operation
REDUCED RANGE
24Vdc
IN line
N.O.
Has to be set to 24 V DC at startup
FUNCTION EARTH
Connect to earth