Project configuration
Operating Manual PSEN sc L 3/5 series
1005056-EN-01
| 27
C
The allowance depends on the height of the scan plane, the detection capability and
the ambient light
5.1.2
Horizontal application with stationary danger zone
A horizontal application has been achieved when the safety laser scanner is aligned at an
angle of max. 30° with the floor level.
[1]
[2]
[3]
[4]
Fig.: Schematic representation minimum distance from the start of the protected area to the danger
zone
Legend
[1] Danger zone
[2] Area covered by the laser beam
[3] Safety laser scanner
[4] Minimum distance to the danger zone (corresponds max. to the operating range of
the safety laser scanner)
The following applies for these applications:
S = K * (t
1
+ t
2
) + Z
T
+ Z
R
+ C