Operation
Operating Manual PSEN sc L 3/5 series
1005056-EN-01
| 73
10
Operation
10.1
Display during normal operation
Message in the display
Status
Description/measure
Icon
Text
CLEANW2
The front panel must be cleaned
Decommission the safety laser scan-
ner.
Clean the safety laser scanner’s
DLDNC
Download of a configuration or a re-
port
A configuration or a report is down-
loaded.
The status of the network is checked The status of the safety laser scan-
ner in the network is checked.
ITLOCK1
Safety laser scanner in interlock
condition
The safety laser scanner is in inter-
lock condition. Normal operation is
possible only after a successful re-
start of the safety laser scanner.
INPUTCF1
Faulty input
Faulty input, e.g. wrong number of
inputs that are used for switching the
zone sets.
NOCONF
No configuration available
No configuration for the safety laser
scanner could be found.
The wave function is activated.
The symbol flashes. Select the
safety laser scanner in PSENscan
Configurator and configure it.
MUT
TIMEOUT
Muting has elapsed (timeout).
MUTING ERR Could not activate muting because
the specifications for activating the
muting sensors were not met.
MUTING
Muting on OSSD1 is active.
The OSSDs are in the ON state.
OVERRIDE
ERR
Could not activate override because
the specifications for activation were
not met.