PSS SB DI8O8
14
Operating Manual
0
3
6
9
x 1
0
3
6
9
x 10
SB Address
1 = Supply
2 = Supply
3 = Load Supply
4 = Ground
^
^
^
^
Power
1 2 3 4
1... Ground X2 ...8
Load Supply
Supply
I/O-Group
Device
SB active
1... Load Supply X3 ...8
1... Power X1 ...4
PSS SB DI8O8
301 140
1... X4 ...8
1... X6 ...8
T
0
T
0
T
1
T
1
O
0
I
0
O
1
I
1
O
2
I
2
O
3
I
3
O
4
I
4
O
5
I
5
O
6
I
6
O
7
I
7
1... X7 ...8
1... X5 ...8
X0
160 (6.30")
65 (2.56")
15
(0.59")
60 (2.36")
Group
O
0
I
0
O
1
I
1
O
2
I
2
O
3
I
3
O
4
I
4
O
5
I
5
O
6
I
6
O
7
I
7
Free space for rail-
mounting and for
ventilation
Recommended
free space
for wiring
Installation
Dimensions in mm ("):
H x W x D: 140 x 170 x 65 (5.51 x 6.69 x 2.56)
The module can be attached to a 35 mm DIN-rail (top hat rail) or can be
screwed on to mounting plate using fixing bolts (order no. 311 068).
To affix the module on to a mounting plate, drill 2 x M4 holes (internal
thread) in the mounting plate, as shown in the above diagram (tolerance:
± 0.2 mm/0.01").
Installing the PSS SB DI8O8, dimensions stated in mm (")