Technical details
Operating Manual PSS u2 ES 4IOL
1004880-EN-01
30
Environmental data
Climatic suitability
In accordance with the standard
EN 60068-2-78
Humidity
93 % r. h. at 40 °C
Condensation during operation
Not permitted
Max. operating height above sea level
2000 m
EMC
EN 61131-2 (Zone B)
Vibration
In accordance with the standard
EN 60068-2-6
Frequency
8,4 - 150 Hz
Amplitude
0,35 mm
Acceleration
10 m/s²
Shock stress
In accordance with the standard
EN 60068-2-27
Acceleration
150 m/s²
Duration
11 ms
Airgap creepage
In accordance with the standard
EN 61131-2
Overvoltage category
II
Pollution degree
2
Protection type
In accordance with the standard
EN 60529
Housing
IP20
Mounting area (e.g. control cabinet)
IP54
Mechanical data
Material
Housing
PPE
Mounting type
plug-in
Dimensions
Height
110,8 mm
Width
12,5 mm
Depth
72,5 mm
Where standards are undated, the 2017-07 latest editions shall apply.