HUNTER-PRO 896 Installation Guide
17
3.1.2
Connecting a Detector (without EOL resistor)
Connecting NC detector with no EOL resistor is done according to the following
diagram. The tamper can be connected in one of two ways:
A. To the TMPR input on the system’s PCB.
B. As a “24 hours” separate zone.
Zon
e
Commo
n
Commo
n
Ta
mper
Zo
ne
+
-
TMPR NC RELAY NC
12
V
(+
)
for de
te
ct
o
r’s
voltage
(-) GN
D
Figure 6 - Connecting DEFENDER PIR without EOL resistor
3.1.3
Connecting a Detector using One EOL Resistor
Connecting NC detector with one EOL resistor is done according to the next diagrams.
The tamper needs be connected to the TMPR input on the control panel’s PCB or as a
“24 hours” separate
Note
: When connecting NO detector, configure the zone input accordingly (see section
5.3.1).
Connecting EOL resistor to NC DEFENDER PIR Detector
PIR (NC)
10
K
¼W
Zone
(-)
+
-
TMPR NC
RELAY NC
Zone
Common
10K ¼W
Zone
Common
Common
Tamper
Zone
10K ¼W
10K ¼W
+
-
TMPR NC
RELAY NC
One EOL resistor
connected to NC detector
One EOL resistor in serial to
the relay and the tamper
Separate connections for
the relay and the tamper,
each with its EOL resistor