HUNTER-PRO 896 Installation Guide
35
Note
: To turn off the buzzer, press long
. In case a new fault occur the buzz
returns. Only after all faults are handled, the red LED ceases to blink and the default
display appears.
3.3.1
Setting Time & Date
USER MENU
Choose 1,2...
8
Master/User
Code
9
Enter time (HH:MM format) and
Enter Date and then
Notes
:
Use
and
to move the cursor to the left and right.
The user code must be enabled by the installer to set the time.
Another way to access the User Menu:
Installer Code
3.4 Faults
Display
Faults are displayed according to the various displaying types in the system (see the
user guide for details).
3.4.1
In PIMA Fast Display
The I/O-WN wireless receiver faults:
Indi. Fault
L
Low battery of detector
V
No signal received from detector on a preset time
F
Detector’s tamper is opened
L - - - - - - - - - - - - - - -
- - - - - F - - - - - - V - - -
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
17 18 19 20 21 2223 24 25 26 27 28 29 30 31 32
Faults display for example: low battery on zone 17,
no signal received from zone (detector) 7, zone
#14’s tamper has been opened.
Note
: When the display is set to “Fast Display” and a battery/tamper/supervision fault
occurs, the display will automatically be set to “Open Zones Scan”. When faults are all