HUNTER-PRO 896 Installation Guide
47
5.3.2.1 Zone
Sensitivity
Sensitiv.(X50mS)
8
Set the zones’ sensitivity in milliseconds. Sensitivity means,
the time a zone has to be opened to trigger an alarm. The number entered is multiplied
by 50. In the example screen, entering 8 means a sensitivity of 8 times 50, i.e. 400 ms.
The sensitivity menu appears after pressing
in zone responses menu.
5.3.3 Zone
Name
2
ENTR
ENTR
NEXT
Zones
ENTER/NEXT/END
Zone Name
ENTER/NEXT/END
Zone Number: 1
X
2
Set the zones’ names. A name can have up to 13 characters.
5.3.4 Partitioning
2
ENTR
ENTR
NEXT
x3
Zones
ENTER/NEXT/END
Partitioning
ENTER/NEXT/END
Set the partitions to which the zones are allocated.
Setting the partitions along with setting the keypads’
partitions determines the nature of the system (i.e. Split
System/ Partitioned System).
Marking “+” allocates a zone to a corresponding partition.
Part. For Zone1
+---_-----------
Drawing 6 - Allocating
zones to a partition
For more details on partitions, refer to chapter 2.
5.3.5 Partitions
Names
2
ENTR
ENTR
NEXT
x4
Zones
ENTER/NEXT/END
Partition Name
ENTER/NEXT/END
Partition1 Name
Partition 1
The partition’s name will appear on every allocated keypad. To enable the displaying of
partitions:
5
ENTR
Display Type:
Show Part Name
BACK
Enter
Master
Code
Note
: Partitions names can only be displayed in partitioned keypads