5.4.1.2
MS1 Report Parameters
A A 1 2 P F D M O L T W I R
+ + + + + + + + + + + + + + 1
Set the type of events to be reported to MS1.
Par.
Alarm\Event
A
Alarms
A
Anti-Mask
1
Special
Burglary
1
2
Special
Burglary
2
P
Panic
F
Fire
D
Duress/Hold-up
M
Medical
O
Open/Close by Phone (PSTN)
L
Failures
T
Periodic
Tests
W
Smart Remote Test: When the system is armed, 2 rings and hang
up triggers the system to dial to the MS and send a TEST event
I
Technician Code Entered: a report sent to MS when technician
code is entered
R
Send Open/Close events by radio
To save,
.
5.4.1.3
Test Time and Interval
Test Time:00:00
Interval:24 Hrs
Set time and interval to send test events to the MS. When leaving the test time 00:00,
the system will ignore it and act according to the interval time only. When changing it
to any other time, the system will act according to both test time and the interval (e.g.
if you set Test time to 23:00 and Interval to 3 Hrs, then test reports will be sent every
3 hours
and
everyday at 23:00. If you leave the time 00:00 and set the interval to
168, then the reports will be sent once a week).
The interval time starts when connecting the system to power.
.
5.4.1.4
Radio Test Interval
Radio Tst. Inter
Hrs:24 Min.s:0
Set the radio test interval. See the previous sub-section for how-to.
.