68
HUNTER-PRO 896 Installation Guide
3. Set output 4 on OUT-1000 to trigger Internal Siren output type in alarm:
7
ENTR
ENTR
NEXT
ENTR
Output Configur.
ENTER/NEXT/END
OUT-1000 Outputs
ENTER/NEXT/END
Output 4
X3
Output 4
Internal Siren
ENTR
Part. For OUT 1
++++++++++++++++
PD
-+
1
ENTR
Pick output No. 4
Set output’s output type
Set output’s partitions
Set output’s polarity & active in disarm
Output’s No.
NEXT
X3
5.9
Key #8
: Full Programming
5.9.1 System
Default
Initialize the system to factory defaults.
8
ENTR
ENTR
Full Programming
ENTER/NEXT/END
System Defaults
ENTER/NEXT/END
Are You Sure?
ENTER/NEXT/END
.
to confirm.
When system initialization is executed:
Defaulting
25
Please Wait...
. A countdown from 25 to
zero ends with this message:
Syst.Defaulted
Press END
.
5.9.2 Local
Download
8
ENTR
ENTR
NEXT
Full Programming
ENTER/NEXT/END
Local Download
ENTER/NEXT/END
Use this menu to program HUNTER-PRO 896 with the COMAX upload/download
software. COMAX runs on a local computer that connects to the system using LCL-11A
adaptor and the keypad (see section
4.1 for connecting with LCL-11A and the COMAX
User Guide). Pressing
enters the system to standby state, waiting to receive data.
Immediately press ‘Local’ icon
in COMAX to start the process. Wait until
“Connected” message is displayed on the COMAX status bar. You can now start
programming.