24
1·IFAN0 ,Setting the air input when igniting, default
value is 12 (Fig.28)
Fig.28
2 IFAN1 ~ IFAN4, Setting the air input for Fire level 1 ~4,
the default value is:
IFAN1 8
IFAN2 10
IFAN3 12
IFAN4 14
(Fig.29)
Fig.29
3. FEED0,·Setting the feeding speed when igniting, the
default value is 24 (Fig. 30)
Fig. 30
4·FEED1~FEED4, Setting the feeding speed for fire
level 1~4, all the default value is “1” (Fig.31)
Fig.31
5. FEED1PR ~ FEED4PR,
Setting the feeding
period time
for
fire level
1 ~ 4
, the default value is
FEED1PR 5
FEED2PR 4
FEED3PR 3
FEED4PR 2
(Fig. 32)
6. FAN1 ~ FAN4, setting the hot air blower fan for fire
level 1 ~ 4, the default value is
FAN1 15
FAN2 20
FAN3 25
FAN4 35
(Fig.32)
Fig.32
20·Setting the auto ash cleaning time
,
For example:
Auto clean the ash in every 4 hours (Fig 33)
Fig.33
21·Setting the time delay of feeding after successful
ignition, for example: start to feeding the pellets in 120s
after ignite successfully (Fig. 34)
6.5 .Control system- Factory model