Squeegee Blade Replacement
The squeegee blades should be replaced when the contact edge becomes worn. To replace the blades,
remove the squeegee from the machine. Remove the screws on the front part and on the rear part of the
squeegee, the steel straps, and the worn rubber blades. Perform the inverse procedure and assemble the
new blades, then adjust the squeegee.
Vacuum Motor Maintenance
The vacuum motor must be checked and cleaned. The motor carbon brushes should be checked every six
months and replaced, if necessary. After removing the key from the dashboard, remove one screw at the
center of the dash panel (indicated below) and the vacuum motor cover. Unhook the hook and detach the
plug to extract the motor and release the sponge filter under the motor so that it can be cleaned and
replaced. Check the suction fan from the hose located
in the front part of the vacuum motor. The fan should
appear undamaged and well cleaned. To check the
brushes, first remove the plastic cap, then unscrew
the screws and remove the two plastic supports of the
brushes. Once checked and replaced (if necessary),
the brushes can be easily remounted by reassembling
all elements.
Caution!
Only qualified personnel authorized by Amano Pioneer
Eclipse should perform each maintenance and repair
operation not described under “ordinary maintenance”.
Summary of Contents for CleanStar CS 2000
Page 13: ...Wiring Schematic CS2000 12 Machine Diagrams and Parts List 032408...
Page 15: ...Tanks Cover Group CS2000 14 012507...
Page 17: ...Pad Drive Group CS2000 16 012507...
Page 19: ...Drive Wheel Assembly Group CS2000 18 012507...
Page 21: ...Squeegee Group CS2000 20 032508...
Page 23: ...Handle Group CS2000 22 012507...
Page 26: ......