PDP-433PU
76
1
2
3
4
1
2
3
4
C
D
F
A
B
E
GS1:
Outputting data such as version information, and data from the hour meter and pulse meter
• Output the data according to the order and size of the table below.
Order
Data Contents
Size
Remarks
1
Display information
3 byte
See below
2
Module microcomputer model number
4 byte
5691 or F691
3
Module microcomputer version
3 byte
4
Panel microcomputer version
3 byte
5
Panel /FLASH ROM version
3 byte
6
Hour meter (hour)
5 byte
Unit: H (hour)
7
Pulse meter
7 byte
Unit: 0.01G (10,000,000)
8
Main microcomputer model number
4 byte
5692 or F692
9
Main microcomputer version
3 byte
10
Wide microcomputer version
3 byte
11
Wide /FLASH ROM version
3 byte
Data
Model
MX5
PDP-503MX (initial value)
MX4
PDP-433MX
MD5
Module 50 inches
MD4
Module 43 inches
HD5
PDP-503HD
HD4
PDP-433HD
Display Information
Note: A checksum of 2 bytes is added at the end, but this can be ignored.