8. EACH SETTING AND ADJUSTMENT
8.1 ADJUSTMENT REQUIRED WHEN THE UNIT IS REPAIRED OR REPLACED
1. At shipment, the unit is adjusted to its best conditions. Normally, it is not necessary to readjust even if an assembly is replaced. If the
adjustment is shifted or if it becomes necessary to readjust because of part replacement, etc., perform the adjustment as described below.
2. Any value changed in Service/Factory mode will be stored in memory as soon as it is changed. Before readjustment, take note of the
original values for reference in case you need to restore the original settings.
3. Use a stable AC power supply.
Y DRIVE Assy
No adjustment required
Other assemblies
No adjustment required
POWER SUPPLY Unit
DIGITAL Assy
X DRIVE Assy
No adjustment required
Refer to “8.3 HOW TO CLEAR HISTORY DATA” .
MAIN Assy (
*
)
Execute section [4-5] AUTO ADJUSTMENT of
6.2 [4] INITIALIZE.
Execute section [4-5] AUTO ADJUSTMENT of
6.2 [4] INITIALIZE.
IO AUDIO Assy
Service Panel Assy
Refer to “8.3 HOW TO CLEAR HISTORY DATA” and
“8.4 ADJUSTMENTS WHEN THE SERVICE PANEL
ASSY IS REPLACED”.
Writing of backup data is required.
Refer to the “8.2 BACKUP OF THE EEPROM
(DIGITAL ASSY)”.
PANEL SENSOR Assy
No adjustment required
Backup data are automatically copied during the next
power-off.
When any of the following assemblies is replaced
(
*
) : When replacing the MAIN Assy, be sure to perform the FINAL SETUP.
Summary of Contents for ARP3476
Page 10: ...10 PDP 5020FD 1 2 3 4 A B C D E F 1 2 3 4 2 2 SPECIFICATIONS ...
Page 11: ...11 PDP 5020FD 5 6 7 8 5 6 7 8 A B C D E F ...
Page 12: ...12 PDP 5020FD 1 2 3 4 A B C D E F 1 2 3 4 2 3 PANEL FACILITIES Front Section ...
Page 13: ...13 PDP 5020FD 5 6 7 8 5 6 7 8 A B C D E F Rear Section ...
Page 14: ...14 PDP 5020FD 1 2 3 4 A B C D E F 1 2 3 4 Remote Control Unit ...
Page 15: ...15 PDP 5020FD 5 6 7 8 5 6 7 8 A B C D E F ...
Page 21: ...21 PDP 5020FD 5 6 7 8 5 6 7 8 A B C D E F ...
Page 22: ...22 PDP 5020FD 1 2 3 4 A B C D E F 1 2 3 4 4 BLOCK DIAGRAM 4 1 OVERALL WIRING DIAGRAM 1 2 ...
Page 25: ...25 PDP 5020FD 5 6 7 8 5 6 7 8 A B C D E F OVERALL DIAGRAM PDP 5020FD ...
Page 31: ...31 PDP 5020FD 5 6 7 8 5 6 7 8 A B C D E F ...
Page 71: ...71 PDP 5020FD 5 6 7 8 5 6 7 8 A B C D E F ...
Page 192: ...192 PDP 5020FD 1 2 3 4 A B C D E F 1 2 3 4 9 6 PANEL CHASSIS SECTION ...