166
PDP-5020FD
1
2
3
4
A
B
C
D
E
F
1
2
3
4
Overview
Preparation
Clearing of the hour meter and pulse meter
Aging with CMB MASK 01 (moving ramp)
displayed
NG
FHD signal (1920*1080)/Video 60-Hz sequence
/Dither: ON, L dither: ON, noise: OFF
For the 9th-generation PDPs, interlocked setting for
Voltages Vyknofs1/3/4 is available on the Factory menu or
with RS232C commands, for easier adjustment. Therefore,
in the adjustment flowchart, the interlocked setting function
is used. (Individual setting for each adjustment value is
also possible, as in the conventional setting methods.
Note:
• The initial value for the interlocked setting value is 128,
including for factory preset values.
• See "[3] DRIVE ASSY" of "5.2 DIAGNOSIS FLOWCHART
OF FAILURE ANALYSIS" for calculation of actually used
voltage values.
Vyknofs1 individual
Vyknofs3 individual
Vyknofs4 individual
Vyknofs1,3,4 interlocked
VOL YNOFS1 D
VOL YNOFS3 D
VOL YNOFS4 D
VOL YNOFSA D
[V1F]
[V3F]
[V4F]
[VYF]
Set Voltage
Factory Menu Command
NG
NG
NG
NG
NG
NG
NG
NG
Adjustment completed
RST MASK 09 (R 1023 /G 626 /B 1023)
Pink
RST MASK 14 (R 0 /G 120 /B 120)
Cyan 120
RST MASK 18 (R 626 /G 0 /B 0)
Red 626
RST MASK 19 (R 0 /G 626 /B 0)
Green 626
RST MASK 20 (R 0 /G 0 /B 626)
RST MASK 21 (R 1023 /G 120 /B 120)
RST MASK 22 (R 120 /G 1023 /B 120)
RST MASK 23 (R 120 /G 120 /B 1023)
Blue 626
Red 1023+
Green 1023+
Blue 1023+
NG
NG
NG
NG
NG
NG
NG
NG
NG
NG
NG
NG
NG
NG
NG
Definition of tones for the measuring
signals
OK
OK
Checking VOL OFFSET (max)
(RST MASK 18: Red 626)
OK
Checking VOL OFFSET (max)
(RST MASK 19: Green 626)
OK
Checking VOL OFFSET (max)
(RST MASK 20: Blue 626)
Recovery flowchart (1-1)
Checking VOL OFFSET (min)
(RST MASK 09: Pink)
Recovery flowchart (1-4)
OK
Checking VOL OFFSET (max)
(RST MASK 20: Blue 626)
Checking VOL OFFSET (min)
(RST MASK 09: Pink)
OK
Recovery flowchart (1-3)
OK
Checking VOL OFFSET (max)
(RST MASK 19: Green 626)
Recovery flowchart (2-4)
OK
Checking VOL YNOFSA D (max)
(RST MASK 14: Cyan 120)
OK
Checking VOL YNOFSA D (min)
(RST MASK 21: Red 1023+)
Checking VOL YNOFSA D (min)
(RST MASK 22: Green 1023+)
OK
OK
Checking VOL YNOFSA D (min)
(RST MASK 23: Blue 1023+)
Recovery flowchart (2-3)
OK
Recovery flowchart (1-2)
OK
Checking VOL OFFSET (min)
(RST MASK 18: Red 626)
Checking VOL YNOFSA D (min)
(RST MASK 23: Blue 1023+)
OK
Checking VOL YNOFSA D (max)
(RST MASK 14: Cyan 120)
Recovery flowchart (2-1)
OK
OK
Checking VOL YNOFSA D (min)
(RST MASK 21: Red 1023+)
Recovery flowchart (2-2)
Checking VOL YNOFSA D (min)
(RST MASK 22: Green 1023+)
Main flowchart (2)
OK
Checking VOL YNOFSA D (min)
(RST MASK 21: Red 1023+)
OK
Checking VOL YNOFSA D (min)
(RST MASK 22: Green 1023+)
OK
Checking VOL YNOFSA D (min)
(RST MASK 23: Blue 1023+)
OK
Checking VOL YNOFSA D (max)
(RST MASK 14: Cyan 120)
Main flowchart (1)
OK
Checking VOL OFFSET (min)
(RST MASK 09: Pink)
OK
Checking VOL OFFSET (max)
(RST MASK 18: Red 626)
OK
Checking VOL OFFSET (max)
(RST MASK 19: Green 626)
OK
Checking VOL OFFSET (max)
(RST MASK 20: Blue 626)
Range of margin measuring
Read the voltage within the hysteresis (stricter value).
Definition of limits for the voltage margins
(abnormal lit/dead cells)
Interlocked settings for Voltages Vyknofs1/3/4
Abnormal lit cells:
• Five or fewer abnormal cells on the whole screen
• Two or fewer abnormal cells within a radius of 1 cm
Abnormal dead cells
• Fifteen or fewer abnormal cells on the whole screen
• Two or fewer abnormal cells within a radius of 1 cm
∗
: Abnormal cells visually recognizable at a distance of
1 meter from the panel must be counted.
∗
: Cells displayed abnormally for less than one second
are not counted as abnormal cells.
V
Read the voltage
within this range.
Erroneous discharge
Adjustment
value m+1
Adjustment
value m
Adjustment
value n
Adjustment
value n-1
Erroneous discharge
No erroneous
discharge
• Re-replacement of the panel
• Replacement of the DRIVE Assy
Replacement with the parts
for service
Summary of Contents for ARP3476
Page 10: ...10 PDP 5020FD 1 2 3 4 A B C D E F 1 2 3 4 2 2 SPECIFICATIONS ...
Page 11: ...11 PDP 5020FD 5 6 7 8 5 6 7 8 A B C D E F ...
Page 12: ...12 PDP 5020FD 1 2 3 4 A B C D E F 1 2 3 4 2 3 PANEL FACILITIES Front Section ...
Page 13: ...13 PDP 5020FD 5 6 7 8 5 6 7 8 A B C D E F Rear Section ...
Page 14: ...14 PDP 5020FD 1 2 3 4 A B C D E F 1 2 3 4 Remote Control Unit ...
Page 15: ...15 PDP 5020FD 5 6 7 8 5 6 7 8 A B C D E F ...
Page 21: ...21 PDP 5020FD 5 6 7 8 5 6 7 8 A B C D E F ...
Page 22: ...22 PDP 5020FD 1 2 3 4 A B C D E F 1 2 3 4 4 BLOCK DIAGRAM 4 1 OVERALL WIRING DIAGRAM 1 2 ...
Page 25: ...25 PDP 5020FD 5 6 7 8 5 6 7 8 A B C D E F OVERALL DIAGRAM PDP 5020FD ...
Page 31: ...31 PDP 5020FD 5 6 7 8 5 6 7 8 A B C D E F ...
Page 71: ...71 PDP 5020FD 5 6 7 8 5 6 7 8 A B C D E F ...
Page 192: ...192 PDP 5020FD 1 2 3 4 A B C D E F 1 2 3 4 9 6 PANEL CHASSIS SECTION ...