104
AVIC-W8400NEX/XNUC
1
2
3
4
A
B
C
D
E
F
1
2
3
4
8.5 DEVICE NUMBER REWRITING (UC MODEL ONLY)
When replacing SOC Unit, it is necessary to rewrite device number to original one for iDatalink user.
Otherwise the activated iDatalink Maestro module will not be used due to mismatch of device number.
About Device Number
Device Number of the unit is same as the serial number.
Check the serial number label of the unit.
How to Rewrite Device Number
1. Enter the Test Mode.
[How to enter the Test Mode for service]
1. Start the product and wait until the map is displayed.
2. Press "Vol+", "Vol-", "Vol+" and "Vol-" in that order.
3. While pressing " (MODE)", press " (MENU)" twice and " (HOME)" twice.
4. Release " (MODE)".
5. Press and release " (MODE)".
6. Product restart starts automatically, and it displayed the Test Mode Main Menu.
2. Select and enter "29. Device Number" in Main Menu.
3. Rewrite the serial number.
Allocation of Key Operation
(Long press)
: Move Set Value cursor to right
VOLUME-(Long press)
: Move Set Value cursor to left
: Change Set Value (+)
VOLUME-
: Change Set Value (-)
(MODE)
: Execute Device Number writing
BACK
: Return to Main Menu
Description
"Device Number" displays the currently written Device Number.
Set the Device Number (serial number of the unit) to "Set Value".
[ MODE] is pressed, the writing is executed.
When the writing is completed, "Device Number" is updated.
If an error is detected, ERROR CODE is displayed.
Display
Description
4
Device Number writing is failed.
6
Acquisition of Device Number is failed.