Audio Master Clock frequency adjustment
No.
Measuring point
Adjusting point
Content of adjustment
TC101
Frequency counter : 11.289 6 MHz ± 20 Hz
1
CLKF
TC102
Frequency counter : 12.288 MHz ± 20 Hz
2
CLK6
1. Source ON.
2. Monitor CLKF (frequency counter and high frequency probe are required) and adjust TC101 to match
the frequency.
3. Monitor CLK6 (frequency counter and high frequency probe are required) and adjust TC102 to match
the frequency.