CDJ-100S
3
Additional Laser Caution
1. Laser Interlock Mechanism
The position of the switch (S1) for detecting loading
completion is detected by the system microprocessor, and
the design prevents laser diode oscillation when the switch
is not in LPS1 terminal side (when the mechanism is not
clamped and LPS1 signal is high level.) Thus, the interlock
will no longer function if the switch is deliberatery set to
LPS1 terminal side. ( if LPS1 signal is low level ).
In the test mode
∗
the interlock mechanism will not function.
Laser diode oscillation will continue, if pin 33 of CXA1782CQ
(IC101) on the MOTHER BOARD ASSY is connected to
GND, or pin 43 of IC701 (LDON) is connected to low level
(ON), or else the terminals of Q101 are shorted to each
other (fault condition).
2. When the cover is opened, close viewing of the objective
lens with the naked eye will cause exposure to a Class 1
laser beam.
∗
: Refer to page 34.
IMPORTANT
T H I S P I O N E E R A P P A R A T U S C O N T A I N S
LASER OF CLASS 1.
SERVICING OPERATION OF THE APPARATUS
S H O U L D B E D O N E B Y A S P E C I A L L Y
INSTRUCTED PERSON.
LASER DIODE CHARACTERISTICS
MAXIMUM OUTPUT POWER: 5 mw
WAVELENGTH: 780 – 785 nm
LABEL CHECK (for WY type)