29
CDS-9036ZT
1)Precautions
•
This unit uses a single power supply (+5V) for the reg-
ulator. The signal reference potential, therefore, is
connected to REFO(approx. 2.5V) instead of GND.
If REFO and GND are connected to each other by mis-
take during adjustments, not only will it be impossi-
ble to measure the potential correctly, but the servo
will malfunction and a severe shock will be applied to
the pick-up. To avoid this, take special note of the fol-
lowing.
Do not connect the negative probe of the measuring
equipment to REFO and GND together. It is especially
important not to connect the channel 1 negative
probe of the oscilloscope to REFO with the channel 2
negative probe connected to GND.
Since the frame of the measuring instrument is usual-
ly at the same potential as the negative probe, change
the frame of the measuring instrument to floating sta-
tus.
If by accident REFO comes in contact with GND,
immediately switch the regulator or power OFF.
•
Always make sure the regulator is OFF when connect-
ing and disconnecting the various filters and wiring
required for measurements.
•
Before proceeding to further adjustments and mea-
surements after switching regulator ON, let the player
run for about one minute to allow the circuits to stabi-
lize.
•
Since the protective systems in the unit's software are
rendered inoperative in test mode, be very careful to
avoid mechanical and /or electrical shocks to the sys-
tem when making adjustment.
•
Disc detection during loading and eject operations is
performed by means of a photo transistor in this
unit.Consequently, if the inside of the unit is exposed
to a strong light source when the outer casing is
removed for repairs or adjustment, the following mal-
functions may occur.
*During PLAY, even if the eject button is pressed,the
disc will not be ejected and the unit will remain in
the PLAY mode.
*The unit will not load a disc.
When the unit malfunctions this way, either re-posi-
tion the light source, move the unit or cover the
photo transistor.
•
When loading and unloading discs during adjustment
procedures, always wait for the disc to be properly
clamped or ejected before pressing another key.
Otherwise, there is a risk of the actuator being
destroyed.
•
Turn power off when pressing the button /FF or the
button REV key for focus search in the test mode. (Or
else lens may stick and the actuator may be dam-
aged.)
2)Test Mode
The CDS-9036ZT/ES is used together with a CD con-
trol unit(KEH-M8276ZT/X1N/ES) to make adjustment.
For adjustment, keys of the CD control unit are used.
For your reference, how to enter Test mode and oper-
ate keys when using a CD control unit are shown be-
low. The keys mentioned in the explanation of adjust-
ment are of a CD control unit(KEH-M8276ZT/X1N/ES).
•
Entering Test mode
Short-circuit the probes indicated as "CD TEST" on
the substrate of the CDS-9036ZT/ES, then set ACC or
BACK UP to ON.
•
Cancelling Test mode
Set ACC or BACK UP to OFF.
•
SINGLE/4TRK/10TRK/32TRK will continue to operate
even after the key is released.Tracking is closed the
moment C-MOVE is released.
•
JUMP MODE resets to SINGLE as soon as power is
switched OFF.
6. ADJUSTMENT
6.1 CD
CD TEST
CONTROL UNIT(SIDE A)
Short-circuit these two probes.
Summary of Contents for CDS-9036ZT/ES
Page 4: ...4 CDS 9036ZT 2 2 EXTERIOR ...
Page 6: ...6 CDS 9036ZT 2 4 CD MECHANISM MODULE ...
Page 11: ...11 CDS 9036ZT 5 6 7 8 5 6 7 8 D C B A A B B b ...
Page 12: ...12 CDS 9036ZT 1 2 3 4 2 3 4 D C B A 1 B a B a B b CONTROL UNIT S7 B PICKUP UNIT SERVICE ...
Page 13: ...13 CDS 9036ZT 5 6 7 8 5 6 7 D C B A 8 B a C B a B b C PHOTO UNIT CXB3043 ...
Page 14: ...14 CDS 9036ZT 1 2 3 4 2 3 4 D C B A 1 B b B a B b ...
Page 15: ...15 CDS 9036ZT 5 6 7 8 5 6 7 D C B A 8 B b B a B b A ...
Page 19: ...19 CDS 9036ZT ...
Page 22: ...22 CDS 9036ZT 1 2 3 4 2 3 4 D C B A 1 CONTROL UNIT A A ...
Page 23: ...23 CDS 9036ZT 5 6 7 8 5 6 7 D C B A 8 SIDE B A ...
Page 25: ...25 CDS 9036ZT D C B A 1 2 3 4 1 2 3 4 SIDE B B CONTROL UNIT S7 B C ...
Page 32: ...32 CDS 9036ZT Grating waveform Ech Xch 20mV div AC Fch Ych 20mV div AC 45 0 75 60 30 90 ...