CT-L5
24
NCT-111 (3 kHz)
VR2701 (Main Unit)
(Refer to Fig. 6–4)
No.
Mode
Input Signal/Test Tape
Adjustment Points
Measurement Points
Adjustment Value
Remarks
PLAY
1
TP R (W183)
( MAIN UNIT)
3000 Hz Hz
(1) Tape Speed Confirmation
(1) Recording Bias Adjustment
¶
After the adjustment, caution should be exercised so as not to become under bias by checking the distortion rate.
STD-331E test tape
(Playback: 10 kHz, –20 dB)
Head azimuth
adjustment Screw
(Fig. 6–4)
Remarks
PLAY
1
TP L (W185)
TP R (W183)
( MAIN UNIT)
Max. Playback
signal level
(2) Head Azimuth Adjustment
¶
This unit is equipped with auto tape selector.
¶
Do not switch between forward and reverse operation with the screwdriver inserted.
+10
–10
6.2.1 Playback Section
After adjustment, apply silicon
bond to the head azimuth
adjustment screw.
VR2301
PLAY
1
(3) Playback Level Adjustment
¶
Since this adjustment determines playback DolbyNR level, Perform it carefully.
L ch
R ch
VR2302
TP L (W185)
TP R (W183)
( MAIN UNIT)
6.2.2 Recording Section
VR2801
REC/
PAUSE
1
Input a 315Hz signal to the AUX
terminal of XC-L5.
∗
L ch
R ch
VR2802
TP L (W185)
TP R (W183)
( MAIN UNIT)
–3.7 dBV
Input signal level
–23.7 dBV
REC
=
PLAY
2
Load the STD–632 test tape and
record/playback the 315Hz and
10kHz signals. (see the Note below)
Repeat adjustment until playback level of
the 10kHz signal is within 0.5dBV ±0.5dB
from that of the 315Hz signal.
(2) Recording Level Adjustment
VR2441
REC/
PAUSE
1
L ch
R ch
VR2442
TP L (W185)
TP R (W183)
( MAIN UNIT)
Input signal level
–7.7 dBV
REC
=
PLAY
2
STD–632 test tape and record/
playback the 315Hz signal.
Repeat recording, playback and
adjustment until playback level of the
315Hz signal becomes –7.7dBV±0.5dB.
Note: Set the 10kHz input signal level to the same value as the 315Hz input signal level of step 1.
Input a 315Hz signal to the AUX
terminal of XC-L5.
∗
No.
Mode
Input Signal/Test Tape
Adjustment Points
Measurement
Points
Adjustment
Value
Remarks
No.
Mode
Input Signal/Test Tape
Adjustment Points
Measurement
Points
Adjustment
Value
STD-331E test tape
(Playback: 315 Hz, 0 dB)
Remarks
No.
Mode
Input Signal/Test Tape
Adjustment Points
Measurement
Points
Adjustment
Value
Remarks
No.
Mode
Input Signal/Test Tape
Adjustment Points
Measurement
Points
Adjustment
Value
*
: In case of adjustment as a single unit, enter the signal at 13P(RECL) and 15P(RECR) of CN2601(MAIN UNIT). At this time, connect an
output buffer amplifier to the oscillator, and then connect a series resistor (180
Ω
) after the impedance has become sufficiently low. (For
MPX filter impedance matching)
FWD adjustment
REV Confirmation
( 3000 Hz Hz )
+60
–60
Summary of Contents for CT-L5