6. ADJUSTMENT
6.1 CD ADJUSTMENT
1) Cautions on adjustments
• In this product the single voltage (3.3V) is used for the
regulator. The reference voltage is the REFO1 (1.65V)
instead of the GND.
If you should mistakenly short the REFO1 with the GND
during adjustment, accurate voltage will not be obtained,
and the servo’s misoperation will apply excessive shock
to the pickup. To avoid such problems:
a. Do not mix up the REFO1 with the GND when
connecting the (-) probe of measuring instruments.
Especially on an oscilloscope, avoid connecting the (-)
probe for CH1 to the GND.
b. In many cases, measuring instruments have the same
potential as that for the (-) probe. Be sure to set the
measuring instruments to the floating state.
c. If you have mistakenly connected the REFO1 to the GND,
turn off the regulator or the power immediately.
• Before mounting and removing filters or leads for
adjustment, be sure to turn off the regulator.
• For stable circuit operation, keep the mechanism
operating for about one minute or more after the
regulator is turned on.
• In the test mode, any software protections will not
work. Avoid applying any mechanical or electrical
shock to the mechanism during adjustment.
• The RFI and RFO signals with a wide frequency range
are easy to oscillate. When observing the signals,
insert a resistor of 1k ohms in series.
• The load and eject operation is not guarantied with the
mechanism upside down. If the mechanism is blocked
due to mistaken eject operation, reset the product or
turn off and on the ACC to restore it.
2) Test mode
This mode is used to adjust the CD mechanism module.
• To enter the test mode.
While pressing the 4 and 6 keys at the same time, reset.
• To exit from the test mode.
Turn off the ACC and back up.
Notes:
a. During ejection, do not press any other keys than the
EJECT key until the loaded disc is ejected.
b. If you have pressed the (
→
) key or (
←
) key during focus
search, turn off the power immediately to protect the
actuator from damage caused by the lens stuck.
c. For the TR jump modes except 100TR, the track jump
operation will continue even if the key is released.
d. For the CRG move and 100TR jump modes, the tracking
loop will be closed at the same time when the key is
released.
e. When the power is turned off and on, the jump mode
is reset to the single TR (91), the RF amp gain is set to 0dB,
and the auto-adjustment values are reset to the default
settings.
Summary of Contents for DEH-1700
Page 5: ...DEH 1700 XN UC 5 5 6 7 8 5 6 7 8 C D F A B E 1 SPECIFICATIONS ...
Page 6: ...DEH 1700 XN UC 6 1 2 3 4 1 2 3 4 C D F A B E ...
Page 7: ...DEH 1700 XN UC 7 5 6 7 8 5 6 7 8 C D F A B E ...
Page 10: ...DEH 1700 XN UC 10 1 2 3 4 1 2 3 4 C D F A B E 2 2 EXTERIOR DEH 1700 XN UC ...
Page 12: ...DEH 1700 XN UC 12 1 2 3 4 1 2 3 4 C D F A B E 2 3 EXTERIOR DEH 7 XN UC ...
Page 24: ...DEH 1700 XN UC 24 1 2 3 4 1 2 3 4 C D F A B E 3 3 KEYBOARD UNIT B ...
Page 32: ...DEH 1700 XN UC 32 1 2 3 4 1 2 3 4 C D F A B E A A TUNER AMP UNIT 1 ...
Page 33: ...DEH 1700 XN UC 33 5 6 7 8 5 6 7 8 C D F A B E A SIDE B ...
Page 35: ...DEH 1700 XN UC 35 5 6 7 8 5 6 7 8 C D F A B E B B KEYBOARD UNIT SIDE B A CN831 ...
Page 58: ...DEH 1700 XN UC 58 1 2 3 4 1 2 3 4 C D F A B E 7 2 2 DISPLAY LCD CAW1848 ...
Page 61: ...DEH 1700 XN UC 61 5 6 7 8 5 6 7 8 C D F A B E 8 OPERATIONS ...
Page 62: ...DEH 1700 XN UC 62 1 2 3 4 1 2 3 4 C D F A B E ...