CD-ROM Parameters Page
- 51 -
2.9.5
CD-ROM Parameters Page
Inactivity Timer Multiplier
The inactivity timer multiplier specifies the length of time that the drive will remain
in the hold track state after completion of a SEEK or READ operation. The default
value is 0Dh. (i.e. 8 minutes). Table 2-6-14 gives a complete listing of the Inactivity
Timer Multiplier.
Number of S per M units
The number of S units per M unit field gives the ratio of these MSF address values.
For media conforming to the CD-ROM and CD-DA standard, this value is 60
(3Ch).
Number of F per S units
The number of F units per S unit field gives the ratio of these MSF address values.
For media conforming to the CD-ROM and CD-DA standard, this value is 75(4Bh).
Summary of Contents for DR-706S
Page 2: ...CD ROM SCSI 2 Command Set R e f e r e n c e M a n u a l V e r s i o n 3 1 OB U0077C ...
Page 36: ...Inquiry 23 this page has been left intentionally blank ...
Page 106: ...Read CD ROM Capacity 93 this page has been left intentionally blank ...
Page 124: ...Read Sub Channel 111 this page has been left intentionally blank ...
Page 130: ...Read TOC 117 this page has been left intentionally blank ...
Page 140: ...Request Sense 127 this page has been left intentionally blank ...
Page 172: ...Read CD DA 159 this page has been left intentionally blank ...