background image

14

15

The unit will now turn on after 6 hours (7:00 PM) and turn off 
again after 8 hours (9:00 PM). (See Fig. 11)

Fig. 12

Current 
time 1PM

2PM

3PM

4PM

5PM

6PM

7PM

8PM

9PM

Timer starts 

Unit turns

 

ON

Unit turns

 

OFF

6 hours later

8 hours later

Timer is set to turn ON 
6 hours from current time 

 

 

FF

Timer is set to turn OFF
8 hours from current time  

 

Your remote display

Troubleshoot Your Remote Control

Symptoms

Possible Causes

Solution

The fan speed 
cannot be 
changed. 

Check whether AUTO 
mode is selected.

In AUTO mode, the fan speed is 
set automatically and cannot be 
changed. 

Check whether DRY 
mode is selected.

In DRY mode, the 

FAN SPEED

button is ineffective.
The fan speed can only be changed
in COOL, FAN and HEAT mode.   

 

The temperature 
display is off  

Check whether FAN 
mode is selected. 

In FAN mode, the temperature 
cannot be adjusted. 

The TIMER OFF 
disappears after 
a period of time 

If the TIMER OFF function 
was activated, the operation 
may have finished.  

 

The air conditioner will 
automatically stop at the set 
time and the indicator light will 
turn off.  

The TIMER ON 
indicator disappears 
after a period of time  

If the TIMER ON function 
was activated,the operation 
may have finished. 

 

The air conditioner will 
automatically start at the set 
time and the indicator light will 
turn off. 

There is no sound 
when the ON/OFF 
button is pressed. 

Check whether the signal 
transmitter of the remote 
control is properly directed 
towards the infrared signal 
receiver of the indoor unit.  

Point the remote control 
directly at the receiver
and press the

 

ON/OFF

 

button twice.

 

 

Summary of Contents for KJR-12B/DP(T)-E-1A

Page 1: ...Owner s Manual MODEL KJR 12B DP T F 1 KJR 12B DP T E 1A KJR 12B DP T E 2 IMPORTANT NOTE Read this manual carefully before installing or operating your wired remote controller Make sure to save this manual for future reference ...

Page 2: ...tomatically turn off the air condi tioner at a specif ied time Allows the remote control to act as a remote thermostat and relay temperature information from its current location The Auxiliary Electric Heater warms up the unit in cold climates If pressed during HEAT mode the electric heater function becomes ineffective Used to restore the system to its default settings Used to start stop the air c...

Page 3: ...e thermostat and relay temperature information from its current location The Heater warms up the unit in cold climates If pressed during HEAT mode the electric heater function becomes ineffective Used to restore the system to its default settings Used to start stop the air conditioner The UP and DOWN buttons are used to adjust the temperature The SWING button starts and stops the louver movement a...

Page 4: ... speed Displays the selected fan speed Fig 3 Basic Functions The following are instructions for using your air conditioner s basic functions AUTO Function In AUTO mode the unit will automatically select the COOL HEAT FAN or DRY function based on the set temperature 1 Press the MODE button select AUTO 2 Set your desired temperature usingtheUP and DOWN buttons 3 Press the ON OFF button to start the ...

Page 5: ...mode the temperature cannot be changed TIMER ON TIMER OFF FOLLOW ME AUXIL HEATER MODE RESET LOCK FAN SPEED ECO SWING TEMP 1 2 4 3 Fig 5 DRY Function 1 Press the MODE button select DRY 2 Set your desired temperature usingtheUP and DOWN buttons 3 Press the ON OFF button to start the unit NOTE In DRY mode the ECONOMY and FAN SPEED buttons cannot be used TIMER ON TIMER OFF FOLLOW ME AUXIL HEATER MODE ...

Page 6: ...nit every three minutes 2 Press FOLLOW ME button again to turn off this function NOTE The swing function can only be used in SWING mode Follow Me Button TIMER ON TIMER OFF FOLLOW ME AUXIL HEATER MODE RESET LOCK FAN SPEED ECO SWING TEMP Fig 7 Setting Air Flow Direction 1 Press the SWING button to activate the swing function Press this button again to set the louver in the position you want 2 Press ...

Page 7: ...ar on the screen and the unit will turn on after 2 hours b Press TIMER ON button repeatedly to set the time you want the unit to turn on c Wait 3 seconds then the TIMER ON function will be activated The digital display on your remote control will then return to the temperature display Example Setting unit to turn on after 2 5 hours 3sec 1 2 x5 TIMER ON TIMER ON 2 TIMER OFF Function The TIMER OFF f...

Page 8: ...wing 1 Press TIMER ON button The last TIMER ON setting will appear 2 Press TIMER ON button repeatedly until 6 0 H is displayed on remote control 6 hours after 1 00 PM which is 7 00 PM 3 Wait 3 seconds and the TIMER ON function will be activated 4 Then press TIMER OFF button The last TIMER OFF setting will appear 5 Press TIMER OFF button repeatedly until 8 0 H is displayed on remote control 8 hours...

Page 9: ...y be changed in COOL FAN and HEAT mode The temperature display is off Check whether FAN mode is selected In FAN mode the temperature cannot be adjusted The TIMER OFF disappears after a period of time If the TIMER OFF function was activated the operation may have finished The air conditioner will automatically stop at the set time and the indicator light will turn off The TIMER ON indicator disappea...

Page 10: ... 008AEN The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details For Further Details please go to www highseer com 20160303 ...

Reviews: