Additional information
15
77
En
If the following error codes appear on the screen, check the corresponding items in the table.
Signal names for 15-pin mini D-sub connecter
Code
Message
Check
SD04
Powering off. Internal temperature is too high.
Check temperature around the display.
Check if the ambient temperature of the flat screen TV is high.
SD05
Internal protection circuits turning power OFF.
Possible short in the speaker cable.
Check the speaker cable connections between the flat screen TV and the
speakers.
SD11
Powering off. Internal temperature is too high.
Check temperature around TV.
Check if the ambient temperature of the flat screen TV is high.
Pin No. Signal name
Pin No. Signal name
1
R
9
+5 V
2
G
10
GND (ground)
3
B
11
Not connected
4
Not connected
12
SDA
5
Not connected
13
HD
6
GND (ground)
14
VD
7
GND (ground)
15
SCL
8
GND (ground)