58)
REGISTER C REQUEST
Function:
Returns the contents of Register C. (Miscellaneous)
Format:
$ C
Explanation:
Returns function switch setting data in the following format:
C
C8
C7
C6
C5
C4
C3
C2
C1 <C/R>
C1:
Side Repeat on
C2:
Load Start on
C3:
Power On Start on
C4:
Not Used
C5:
Back Color Select (0 = Blue)
C6:
Not Used
C7:
Not Used
C8:
Test Mode on
Execution:
* R C = 0
8 R C <C/R>
R <C/R>
$ C <C/R>
C 0 0 0 0 1 0 0 0 <C/R>
59)
REGISTER D REQUEST
Function:
Returns the contents of Register D. (RS-232)
Format:
$ D
Explanation:
Returns function switch data in the following format:
D
C8
C7
C6
C5
C4
C3
C2
C1:
<C/R>
C1 & C2:
Baud Rate
00: 9600 Baud
01: 4800 Baud
10: 1200 Baud
00: Not used
C3:
Parity (1 = Enable, 0 = Disable)
C4:
Parity (1 = Odd, 0 = Even)
C5:
Stop Bit (1 = 1 Bit, 0 = 2 Bit )
C6:
Data Length (1 = 7 Bits, 0 = 8 Bits)
C7:
TxD Terminator (1 = C/R & L/F, 0 = C/R)
C8:
RS-232C Port Set (1= Controller, 0 = Input Device)
Execution:
* Field Mode (R D = 16)
0 R D <C/R>
R <C/R>
$ D <C/R>
D 0 0 0 0 0 0 0 0 <C/R>
Chapter Four • LD-V8000 Level I & III
4-60
TP 113 v. 2.1 • 2/93
LD-V8000 Level I & III User’s Manual