If the following error codes appear on the screen, check the corresponding items in the table.
Signal assignments for 15-pin D-sub connector
• Power is suddenly turned off.
• The system’s internal temperature has increased. Remove any objects blocking vent or clean.
(See page 15.)
• Check the power control setting. (See page 36.)
• Check the sleep timer setting. (See page 49.)
• Panel sounds/noises
• Panel generated sounds, examples: Fan motor noise, Electrical Circuit Humming/Glass Panel
buzzing are normal operation of a phosphor-based matrix display.
• When you change the Energy Save mode, you may notice a change in the panel sound. This is
normal.
• POWER ON indicator or STANDBY indicator is quickly
flashing.
• Internal protective circuits may have been activated. First turn the main power off by pressing
POWER
on the plasma display, and then turn the power on again in after one minute or more.
• If the problem is not solved with this, contact a Pioneer Service Centre or Pioneer Authorised
Independent Service Company. These are listed on your warranty card.
Code
Message
Check
SD04
and
SD11
Powering off. Internal temperature too high.
Check temperature around PDP.
Check if the ambient temperature of the plasma display is high.
SD05
PDP-507XDA
Internal protection circuit turns power off.
Is there a short in the speaker cable?
PDP-427XDA
Internal protection circuit turns power off.
Check the speaker cable connections between the plasma display and
the speakers.
Contact a Pioneer Service Centre or Pioneer Authorised Independent
Service Company. These are listed on your warranty card.
Problem
Possible solution
Pin No.
Signal assignment
Pin No.
Signal assignment
1
R
9
+5 V
2
G
10
GND (ground)
3
B
11
Not connected
4
Not connected
12
SDA
5
Not connected
13
HD
6
GND (ground)
14
VD
7
GND (ground)
15
SCL
8
GND (ground)