PDP-435PE
54
1
2
3
4
1
2
3
4
C
D
F
A
B
E
• Description on power-down
Data
Power-down Point
0
No power-down
1
Not used (for MR-POWER)
2
Panel-POWER SUPPLY
3
SCAN
4
SCN-5V
5
Y-DRIVE
6
Y-DCDC
7
Y-SUS
8
ADR
9
X-DRIVE
A
X-DCDC
B
X-SUS
C
DIG-DCDC
D
IC4
E
Reservation
F
Power-down point unidentified
GPW: Obtaining panel white-balance adjustment values
Note:
Ignore the 2-byte checksum at the end.
Notes:
• Ignore the 2-byte checksum at the end.
• If a Media Receiver (MR) is connected, the version of the microcomputer inside the MR is displayed at the end.
(Refer to the service manual of the Media Receiver.)
Order
Data
Size
Remarks
1
W/B table currently used
3 bytes
PT1 - PT3
2
Main contrast
4 bytes
0000 - 0511
3
Red contrast of W/B adjustment value
4 bytes
0000 - 0511
4
Green contrast of W/B adjustment value
4 bytes
0000 - 0511
5
Blue contrast of W/B adjustment value
4 bytes
0000 - 0511
6
Main brightness
4 bytes
0000 - 1023
7
Red brightness of W/B adjustment value
4 bytes
0000 - 1023
8
Green brightness of W/B adjustment value
4 bytes
0000 - 1023
9
Blue brightness of W/B adjustment value
4 bytes
0000 - 1023
GS1: Obtaining information on the unit, such as the software version
(Reference) GS2: Obtaining information on the status of the unit
Order
Data
Size
1
Display data
3 bytes
2
Version of the module microcomputer
4 bytes
3
IC4-MANTA version
4 bytes
4
Sequence version (43VIDEO)
4 bytes
5
Sequence version (43PC)
4 bytes
6
Sequence version (50VIDEO)
4 bytes
7
Sequence version (50PC)
4 bytes
Notes:
• Ignore the 2-byte checksum at the end.
• The data expected to be used for service may be "5. Data on temperature" and "15,16. Hour meter".
(
∗
1) Each time hour-meter data are cleared, the accumulated time data are updated. The total for data items 15 and 16 is the total
power-on time after shipment. The accumulated time of cleared hour-meter data cannot be cleared.
(
∗
2) The hour-meter data that indicate driving hours of the panel are displayed on the Factory menu. Upon shipment, the data are
cleared.
Order
Data
Size
Remarks
1
Notifying that the unit is shifting to Standby mode
1 byte
1: OK for shifting to Standby
2
Whether or not the main unit has been adjusted
1 byte
0: Adjusted, 1: Not adjusted
3
With/without backup for adjustment values
1 byte
0: With backup, 1: Without backup
4
Data on power-down
2 bytes 1st byte: 1st PD, 2nd byte: 2nd PD
5
Data on temperature (TEMP1)
3 bytes
000 - 255
6
Abnormality in RST2 (power decrease of DC-DC converter)
1 byte
0: Normal, 1: SD process completed, 2: In the process of SD warning
7
IC4 communication failure
1 byte
0: Normal, 1: SD process completed, 2: In the process of SD warning
8
EEPROM communication failure
1 byte
0: Normal, 1: SD process completed, 2: In the process of SD warning
9
Audio failure
1 byte
0: Normal, 1: SD process completed, 2: In the process of SD warning
10
Volume IC communication failure
1 byte
0: Normal, 1: SD process completed, 2: In the process of SD warning
11
Backup ROM communication failure
1 byte
0: Normal, 1: SD process completed, 2: In the process of SD warning
12
Data on temperature (TEMP1) not obtained
1 byte
0: Normal, 1: SD process completed, 2: In the process of SD warning
13
Operational status of panel protection mechanism
1 byte
0: Protection mechanism not activated, 1: Protection mechanism activated
14
Reservation
2 bytes
∗∗
15
Accumulated time of cleared hour-meter (
∗
1)
7 bytes 1st-5th byte: Hour, 6th-7th byte: Minute
16
Hour-meter (clearable) (
∗
2)
7 bytes 1st-5th byte: Hour, 6th-7th byte: Minute