PDP-436SXE
95
5
6
7
8
5
6
7
8
C
D
F
A
B
E
Data Arrangement
Data
Length
Output Example
ECO
3Byte
QPD
1
Latest "1st PD" data
1byte
A
2
Latest "2nd PD" data
1byte
2
3
Data from the hour meter for the latest PD
8byte
00010020
4
Second latest "1st PD" data
1byte
E
5
Second latest "2nd PD" data
1byte
9
6
Data from the hour meter for the second latest PD
8byte
00008523
7
Third latest "1st PD" data
1byte
4
8
Third latest "2nd PD" data
1byte
3
9
Data from the hour meter for the third latest PD
8byte
00004335
10
Fourth latest "1st PD" data
1byte
2
11
Fourth latest "2nd PD" data
1byte
0
12
Data from the hour meter for the fourth latest PD
8byte
00000945
13
Fifth latest "1st PD" data
1byte
4
14
Fifth latest "2nd PD" data
1byte
0
15
Data from the hour meter for the fifth latest PD
8byte
00000715
16
Sixth latest "1st PD" data
1byte
A
17
Sixth latest "2nd PD" data
1byte
2
18
Data from the hour meter for the sixth latest PD
8byte
00000552
19
Seventh latest "1st PD" data
1byte
A
20
Seventh latest "2nd PD" data
1byte
0
21
Data from the hour meter for the seventh latest PD
8byte
00000213
22
Eighth latest "1st PD" data
1byte
D
23
Eighth latest "2nd PD" data
1byte
0
24
Data from the hour meter for the eighth latest PD
8byte
000001A7
CS
2Byte
27
¶
PD data
0
No PD
1
Not used
2
P-POWER
3
SCAN
4
SCN-5V
5
Not used
6
Y-DCDC
7
Y-SUS
8
Address
9
X-DRIVE
A
X-DCDC
B
X-SUS
C
DIG-DCDC
D
QS (driving stopped)
E
Not used
F
Specification inability
Command
Format
Effective Operation
Modes
Function
Remarks
[QPD]
All operations
To acquire data on the power-down logs
Return data: 3 (ECO)+80(DATA)+2(CS)=85Byte
7
Acquisition of PD logs • • • [QPD]
The command QPD is for acquiring data from the 8 latest power-down (PD) logs.