Recovery flowchart (1-1)...Changing the VOL OFFSET setting voltage
[From the Main flowchart (1)]
RST MASK 12 (Light blue)
Recovery flowchart (1-2)...Changing the VOL OFFSET setting voltage
[From the Main flowchart (1) / Recovery flowchart (1-1)]
RST MASK 10 (Pink)
Display RST MASK 10 (Pink). / [MKS S60]
Replacement of abnormal circuits or
re-replacement of the panel re
q
uired
N
o
Yes
Set VOL OFFSET to the current setting value plus 112. / [VOF
***]
Gradually increase the VOL OFFSET value until disappear the
discharge (lit cell).
The VOL OFFSET value must be 133 or less.
Current VOL OFFSET > 133?
[To the Recovery flowchart (1-2)]
Display RST MASK 02 (Red). / [MKS S52]
Replacement of abnormal circuits or
re-replacement of the panel re
q
uired
Replacement of abnormal circuits or
re-replacement of the panel re
q
uired
N
o
Yes
Gradually increase the VOL OFFSET value until disappear the
discharge (lit cell).
The VOL OFFSET value must be 133 or less.
N
o
Yes
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
A
Current VOL OFFSET > 133?
Summary of Contents for PDP-5010FD
Page 19: ...PDP 5010FD 19 5 6 7 8 5 6 7 8 C D F A B E ...
Page 20: ...PDP 5010FD 20 1 2 3 4 1 2 3 4 C D F A B E 4 BLOCK DIAGRAM 4 1 OVERALL WIRING DIAGRAM 1 2 ...
Page 23: ...PDP 5010FD 23 5 6 7 8 5 6 7 8 C D F A B E ...
Page 35: ...PDP 5010FD 35 5 6 7 8 5 6 7 8 C D F A B E ...
Page 167: ...PDP 5010FD 167 5 6 7 8 5 6 7 8 C D F A B E ...
Page 178: ...PDP 5010FD 178 1 2 3 4 1 2 3 4 C D F A B E 10 6 PANEL CHASSIS SECTION ...