PDP-505MX
100
1
2
3
4
1
2
3
4
C
D
F
A
B
E
(1) Detach connectors and cables on failed Board.
Data Relay Board (LU)
6 connectors
Common Relay Board
2 connectors
Digital Board
9 connectors
High Voltage
Board
9 connectors
Common Connection Board
7 connectors
Scan Relay Board (U)
5 connectors
Scan Relay Board (D)
5 connectors
Data Relay Board (CU)
11 connectors
Data Relay Board (RU)
8 connectors
Data Relay Board (LD)
6 connectors
Data Relay Board (CD)
11 connectors
Data Relay Board (RD)
8 connectors
Caution:
Be careful of handling cables and connectors to avoid failure. Be sure to take off Heat Sink before detach Data
Relay Board. See next Page for the procedure.
(2) Loosen screws of failed Board and put on good Board.
Data Relay Board (LU)
3 screws
Common Relay Board
15 screws
Digital Board
4 screws
High Voltage
Board
15 screws
Common Connection Board
9 screws
Scan Relay Board (U)
2 screws
Scan Relay Board (D)
2 screws
Scan Relay Connection Board
2 screws
Data Relay Board (CU)
3 screws
Data Relay Board (RU)
4 screws
Data Relay Board (LD)
3 screws
Data Relay Board (CD)
3 screws
Data Relay Board (RD)
4 screws
Caution:
Be careful not to leave screwdriver, screw or screw dust. Be sure to take off Heat Sink before detach Data Relay
Board. See the next page for the procedure.
Summary of Contents for PDP-505MX
Page 7: ...PDP 505MX 7 5 6 7 8 5 6 7 8 C D F A B E ...
Page 21: ...PDP 505MX 21 5 6 7 8 5 6 7 8 C D F A B E ...
Page 46: ...PDP 505MX 46 1 2 3 4 1 2 3 4 C D F A B E Sensor Board IR Board Power Switch Board ...
Page 47: ...PDP 505MX 47 5 6 7 8 5 6 7 8 C D F A B E Button ...
Page 48: ...PDP 505MX 48 1 2 3 4 1 2 3 4 C D F A B E Audio Board ...
Page 49: ...PDP 505MX 49 5 6 7 8 5 6 7 8 C D F A B E ...
Page 50: ...PDP 505MX 50 1 2 3 4 1 2 3 4 C D F A B E PS250 PWR 500W ...