61
PDR-509
Insulation Sheet, etc.
Under Base
Caution :
Do not touch the CD-R CORE Assy to the Under Base.
7.1.3 DIAGNOSIS OF CD-R CORE ASSY
CN101
CN453
CN452
1
1
3
2
CD-R CORE
Assy
A
When diagnosing the CD-R CORE Assy, use the following Flexible Cable and Connector Assys for service.
CN101
↔
CN1 (Pickup)
32P Flexible Cable : PDD1202
• Flexible Cable and Connector Assys for service
2
CN452
↔
CN601 (SERVO MECHANISM Assy)
Connector Assy (9P) : PG09KK-E35
3
CN453
↔
CN551 (LOADING B Assy)
Connector Assy (2P) : PG02KK-E35