69
PDU-50WX2
• Operations : When a microcomputer detected abnormality, turn the power supply to OFF.
• LED display : Green blinks
How to release the shut down state
Turn the power supply ON after having done power off once.
(It is not necessary to turn the AC power OFF.)
How to release the power down state
AC power OFF
↓
Wait for PD LED in the power supply module disappearing
(for around 30 seconds).
↓
Afterwards, wait moreover for five seconds.
↓
Return by AC power ON.
* After power down release, this unit rises up in the standby state.
Examples: LED blinks in the DIGITAL-IIC communication NG
• Operations : When this unit becomes the dangerous state, turn the power supply OFF with the protection circuit.
• LED display : Red blinks
* When protection circuit more than two places almost worked simultaneously, display LED in order to 1st - 2nd.
Examples: LED blinks in the 1st power down = Y-DC/DC CONVERTER, 2nd power down = Y-DRIVE
Number of
blinks
Name
1
Panel Microcomputer NG
2
DIGITAL-IIC communication NG
3
Dewdrop abnormality
4
Temperature abnormality
Number of
blinks
Name
1
Y-DRIVE
2
Y-DC/DC CONVERTER
3
X-DC/DC CONVERTER
4
X-DRIVE
5
Power supply
6
Address junction
7
Address resonance
8
DIGITAL-DC/DC CONVERTER
7.1.2 SHUT DOWN/POWER DOWN DIAGNOSIS BY LED DISPLAY
Shut Down
Power Down
Green LED lights
for 200 msec.
Lights out
for 3 sec
Green LED lights
for 200 msec.
Lights out
for 100 msec
When internal circuit abnormality and other operation abnormality occurred from this unit, self-diagnose display function by STANDBY/ON
(LED) indicator is loaded.
Each NG point by LED blinking and a PD (power down) point are as follows.
1st power-down information
2nd power-down
information
Red LED lights
for 200 msec.
Lights out
for 3 sec
Lights out
for 1 sec
Red LED lights
for 200 msec.
Lights out
for 100 msec
Red LED lights
for 200 msec.
Summary of Contents for PDU-50WX2
Page 23: ...PDU 50WX2 23 ...