30
PRV-LX10
En
System Default Settings
Network
When using this unit on a network, go to
SET UP
section
=
[
System
]
=
[
Network
], and set the
[
Network
] command to
“ON”
. Then go to
SET UP
section
=
[
System
]
=
[
Network
], and set the
[
DHCP/Manual
] command either to use DHCP
(Dynamic Host Configuration Protocol) or input the IP
address used, together with sub-net mask and
Gateway address.
If
“DHCP”
is selected, confirm that a DHCP server in
fact exists. If no server exists, a longer time will be
required for the unit to boot to the idling condition
when the power is turned on. When
“DHCP”
is
SET UP section
=
[System]
=
[Network]
SET UP section
=
[System]
=
[Network]
=
[DHCP/Manual]
=
[DHCP]
SET UP section
=
[System]
=
[Network]
=
[DHCP/Manual]
=
[Manual]
selected, the [
IP Address
] command
will display the
address automatically allocated to the recorder.
Also, setting [
Network
] to
“ON”
makes it possible
to check the MAC address of this unit.
Note:
Be very careful when setting IP address, sub-net
mask, and Gateway addresses. Failure to set the
correct values may not only make it impossible to
connect to a network, but cause malfunctions
throughout the network. If you are unsure of the
proper values to set for these items, consult your
network administrator.
UPS Support
Whenever the power to this unit is turned OFF, the
unit performs a shutdown operation. An unintentional
power interruption results in the power being
disconnected without the shutdown operation being
performed, thus resulting in potential malfunctions. In
order to avoid such malfunctions, the use of an
uninterrupted power supply (UPS) is recommended.
By going to
SET UP
section
=
[
System
]
=
[
UPS
Setting
]
=
[
Model
], you can select
APC Smart-
UPS 750
or
Smart-UPS 500
(Note)
.
Note:
Smart-UPS 500
is for use in Japan only.
Also, if power is interrupted and the UPS operates,
the time before automatic shutdown is initiated can
be set to 30 seconds or 60 seconds (
SET UP
section
=
[
System
]
=
[
UPS Setting
]
=
[
Shutdown
Delay
]). In this way, the shutdown operation will be
avoided if normal power is restored within the
selected time interval.
SET UP section
=
[System]
=
[UPS Setting]
Use the UPS products below, manufactured by
AMERICAN POWER CONVERSION CORP. (APC).
Smart-UPS 750VA
(Part Number: SU750INET)
Connection of other manufacturers’ UPS will not
result in proper operation.