*6: Whether or not the firmware versions for the Encoder board, Decoder board, and drive are identical to those of the
application software is checked. If not identical, the application will not start up. Inconsistency of versions may result in
most cases after replacing the above parts for repair. In such a case, install the latest firmware program.
*7: Initialization of the network is not executed if Network is not set to Enabled on the Function menu. If the network cable is
not connected, initialization of the network is not executed even if Network is set to Enabled. If the DHCP server does not
exist even if DHCP is assigned in the network setting, the startup time will be delayed more than 30 seconds.
*8: Normally, the application starts up. However, in the following cases, the application does not start up:
1
When the Encoder or Decoder board could not be detected
In this case, "-NO-BOARD-DECODER" or "-NO-BOARD-ENCODER" is displayed on the FL display, and only the
STANDBY/ON button will be active.
2
When the firmware version for the Encoder board, Decoder board, or drive is not identical to that in the application
software
In this case, "ERROR FIRM-VERSION" is displayed on the FL displays, and only the [STANDBY/ON] button will be
active. This may result after replacing the PCI board with one having the old firmware when repairing. In this case,
press the [STANDBY/ON] button while holding the [ENTER] button on the front panel pressed, and install the latest
firmware program.
3
When the [STANDBY/ON] button is pressed while the [ENTER] button on the front panel is held pressed, Program-
Install mode is activated. In this case, "PGM-INSTALL" is displayed on the FL displays.
4
If the region set for the drive is different from the destination setting for the unit, Region-Resetting mode is activated.
In this case, "CHANGE-RGN" is displayed on the FL displays.