background image

Basic Functions

9

10

Your air conditioning unit has two

timer-related features:

• 

TIMER ON

 - Sets the amount of 

                      delay before the unit 

                      will automatically 

                      turn on.

• 

TIMER OFF

 - Sets the amount of 

                       time before the unit 

                       will turn itself off.

TIMER ON:

The TIMER ON feature allows you to 

set a fixed period of time, after 

which the unit will automatically 

turn itself on. For example, it can be 

scheduled to turn on when the user 

arrives home from work.

1. Press the TIMER button. The 

timer on indicator     and the time 

amount will display.

Note:

 This value indicates the 

          amount of time left before 

          the unit turns itself on. 

          Activating TIMER ON with a 

          value of 2h at 1 p.m. will turn 

          the unit on at 3 p.m.

2. Press the temp      or temp      

    buttons repeatedly to configure

    the time that the unit should

    turn itself on.

3-4. After 3 seconds, the TIMER ON

       feature will be active. The 

       digital display on your remote    

       controller will then return to 

       displaying the temperature. 

 

The    indicator remains on and the 

feature is now activated.

Setting the TIMER function

Setting the TIMER function

Basic Functions

Ex:

 Setting the unit 

      to turn on after 

      2.5 hours.

Ex:

 Setting the unit 

      to turn off after 

      5 hours.

TIMER OFF:

The TIMER OFF feature allows you to

set a fixed period of time, after 

which the unit will automatically 

turn itself off. For example, it can be 

scheduled to turn off when the 

user leaves home for work.

1. Press the TIMER button. The 

    timer off indicator     and 

    the time amount will display.

Note:

 This value indicates the 

          amount of time left before 

          the unit turns itself off. 

          Activating TIMER OFF with a 

          value of 5h at 2 p.m. will turn 

          the unit off at 7 p.m.

2. Press the temp      or temp      

    buttons repeatedly to configure

    the time that the unit should

    turn itself off.

3-4. After 3 seconds, the TIMER OFF

       feature will be active. The 

       digital display on your remote    

       controller will then return to 

       displaying the temperature. 

 

The     indicator remains on and 

the feature is now activated.

Note:

 When configuring the TIMER

          ON or TIMER OFF features,

          the configuration process will

          increase/decrease in 30 minute

          increments until the value

          reaches 10 hours. After 10

          hours, the configuration will

          increase/decrease in 1 hour

          increments. Either function can

          be turned off by setting the

          timer to “0hr”. 24 hr limit max.

Summary of Contents for RG57A6/BGEFU1

Page 1: ...design and specifications of this product are subject to change without prior notice as development continues Consult with the sales agency or manufacturer for details is a registered trademark of Parker Davis HVAC International Inc Parker Davis HVAC International Inc 3250 NW 107th Ave Doral FL 33172 USA Tel 305 513 4488 Fax 305 513 4499 e mail info pd hvac com Website www pd hvac com Copyright Pa...

Page 2: ...ted and found to comply within the limits for a Class B digital device pursuant to section 15 of FCC law These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with these instructions may cause harmful interference to radio ...

Page 3: ...ld be used within 8 meters of the unit The unit will beep when signals from the remote are received Curtains direct sunlight etc can interfere with the receiver s infrared signal If the remote controller will not be used for more than 2 months be sure to remove its batteries Do not dispose of batteries as unsorted municipal waste Refer to your local laws for the proper disposal of batteries 3 4 Ha...

Page 4: ...temp or temp buttons 3 Press the ON OFF button to start the unit Note Fan speed can t be set when in AUTO mode AUTO Mode Operation Setting Temperatures LCD Screen Icons Indicators Basic Functions 5 6 ON OFF The unit is on when this is displayed Transmission Indicator Displays when the remote sends signals to the indoor unit Timer ACTIVE Displays when the timer is set Timer OFF Displays when the ti...

Page 5: ...uttons 3 Press the ON OFF button to start the unit Note Fan speed can t be set when in DRY mode DRY Dehumidification Mode Basic Functions 1 Press the MODE button to select HEAT mode 2 Set your desired temperature using the temp or temp buttons 3 Press the FAN button to select the fan speed 4 Press the ON OFF button to start the unit Note As the outdoor temperature drops the performance of your uni...

Page 6: ...ting the TIMER function Basic Functions Ex Setting the unit to turn on after 2 5 hours Ex Setting the unit to turn off after 5 hours TIMER OFF The TIMER OFF feature allows you to set a fixed period of time after which the unit will automatically turn itself off For example it can be scheduled to turn off when the user leaves home for work 1 Press the TIMER button The timer off indicator and the ti...

Page 7: ...he TIMER ON feature of the system to turn itself on in 6 hours Configure the TIMER OFF feature of the system to turn itself off in 8 hours Setting the TIMER function The example on page 11 shows how to set the system to turn on after 6 hours operate for 2 hours and then turn itself off See the figure below The remote display will be as shown Note If the user wishes to incorporate the scheduling fe...

Page 8: ...of this moisture has usually evaporated When self clean mode is active the system will clean itself and afterwards will turn itself off automatically This feature can be used as often as needed but is only available in COOL AUTO or DRY mode Turbo Mode Turbo mode forces the unit to reach the set temperature in the quickest time possible In cooling mode this will result in the unit jump starting the...

Reviews: