S-FCRW240B-S
21
5
7
8
5
7
8
C
D
F
A
B
E
6. ADJUSTMENT
Test Point
VR41
Gain Adj
Digital
Voltmeter
AMP ASSY
+
-
A
SIDE A
28
Ω
3 W
Adjustment VR
ATTENTION
¶
Don’ t make speaker terminal short circuit during the power supply injection.
¶
Since the PRIMARY part of the AMP ASSY is not insulated, be careful of electric shock.
¶
Be sure to disconnect the power supply cord before touching the AMP ASSY board.
¶
Discharge the C13, C14 capacitors!
6.1 MEASURING INSTRUMENTS
¶
Provide yourself with the following measuring devices:
(1) Digital voltmeter
(2) Oscilloscope
(3) Attenuator
(4) Low-frequency oscillator
7
7
7
7
7
GAIN Adjustment
(1) Decrease the level of the Adjustment Variable resistors (VR) for the channel to adjusted.
(2) Increase LEVEL VOLUME maximum.
(3) Adjust GAIN (VR41) volume.
¶
Apply the signal to the Line IN of JA201.
¶
As the gain from IN to SPEAKER OUT 53dB(freq. = 50 Hz), input of 10mVrms to Input results in output of 0.72 W
(4.5Vrms/28 W) at SPEAKER OUT
.
¶
After power-supply ON, after waiting abut 10 seconds, it adjustment because, wave form rises behind time for
slow start operation.